(1)電場(chǎng)短路
(1) Electric field short circuit
故障原因:①在安裝時(shí)不小心使陰極針歪。②在清洗后電場(chǎng)內(nèi)殘留有雜物。
Fault cause: ① the cathode needle is crooked due to carelessness during installation. ② Sundries remain in the electric field after cleaning.
解決方法:①拆下電場(chǎng),校正陰極針。②電場(chǎng)內(nèi)的雜物。
Solution: ① remove the electric field and correct the cathode needle. ② Remove sundries in the electric field.
(2)絕緣子短路
(2) Insulator short circuit
故障原因:清洗時(shí)絕緣子上殘留有過(guò)多的清洗劑。
Fault cause: too much cleaning agent remains on the insulator during cleaning.
解決方法:將絕緣子清洗干凈。
Solution: clean the insulator.
(3)高壓變壓器損壞
(3) High voltage transformer damaged
故障原因:聽不到靜電聲,檢查電場(chǎng)沒有短路,而且一開機(jī)即跳閘或燒保險(xiǎn)管。
Fault cause: no static sound can be heard. Check that there is no short circuit in the electric field, and it trips or burns the fuse tube upon startup.
濟(jì)南油煙凈化器
解決方法:更換高壓變壓器。
Solution: replace the high-voltage transformer.
(4)變壓器超溫
(4) Transformer overtemperature
故障原因:由于廚房環(huán)境溫度過(guò)高,通常是設(shè)備工作到高峰時(shí)跳閘。
Fault cause: due to the high ambient temperature in the kitchen, the equipment usually trips at the peak of operation.
解決方法:引入鮮風(fēng)對(duì)油煙凈化設(shè)備進(jìn)行強(qiáng)制降溫。
Solution: introduce fresh air to forcibly cool the oil fume purification equipment.
(5)可控硅損壞
(5) Thyristor damaged
故障原因:此故障表現(xiàn)為電場(chǎng)只放電一次就跳閘保護(hù)或燒保險(xiǎn)管。
Fault cause: this fault is shown as tripping protection or burning of fuse tube when the electric field is discharged only once.
解決方法:更換相同型號(hào)的可控硅。
Solution: replace the thyristor of the same model.
油煙凈化器出現(xiàn)的高壓電場(chǎng)跳閘保護(hù)故障原因解決就是上述所講解的內(nèi)容這樣了,當(dāng)然如果您在使用之前提前做好了預(yù)防措施,那么后期就會(huì)很少出現(xiàn)問(wèn)題了,更多內(nèi)容就來(lái)我們網(wǎng)站http://www.adr7.cn咨詢吧。
The reason for the high-voltage electric field trip protection fault of the oil fume purifier is the content explained above. Of course, if you take preventive measures in advance before use, there will be few problems in the later period. For more information, please visit our website http://www.adr7.cn Consult.