來源:http://www.adr7.cn/     發(fā)布時(shí)間:2022-12-22  

1、風(fēng)管安裝應(yīng)符合設(shè)計(jì)要求
1. The installation of air duct shall meet the design requirements
建筑結(jié)構(gòu)預(yù)留孔洞位置應(yīng)正確,孔洞應(yīng)在風(fēng)管外100毫米以上。建筑結(jié)構(gòu)風(fēng)管與風(fēng)管的連接接口應(yīng)沿氣流方向插入,并采取密封措施。風(fēng)管與風(fēng)機(jī)、風(fēng)機(jī)外殼、空氣處理器等設(shè)備連接的地方,應(yīng)設(shè)置長度應(yīng)為150 ~ 300 mm的柔性短管或按設(shè)計(jì)規(guī)定設(shè)置。柔性短管不應(yīng)用作調(diào)準(zhǔn)和調(diào)平減壓連接管。位于結(jié)構(gòu)變形縫處的柔性短管長度應(yīng)大于變形縫寬度100毫米以上,輸送冷凝水或水汽的風(fēng)管安裝坡度應(yīng)符合設(shè)計(jì)要求。風(fēng)管底部不應(yīng)設(shè)置縱向接頭,風(fēng)管接頭應(yīng)密封。
The position of the reserved holes in the building structure shall be correct, and the holes shall be more than 100mm outside the air duct. The connection interface between the building structure air duct and the air duct shall be inserted along the air flow direction, and sealing measures shall be taken. The flexible short pipe with a length of 150~300 mm shall be set at the place where the air duct connects with the fan, fan housing, air processor and other equipment, or set according to the design regulations. Flexible stub pipes shall not be used as alignment and leveling pressure reducing connecting pipes. The length of the flexible short pipe at the structural deformation joint shall be more than 100mm wider than the width of the deformation joint, and the installation slope of the air duct conveying condensate or water vapor shall meet the design requirements. Longitudinal joints shall not be set at the bottom of the air duct, and the air duct joints shall be sealed.
2、管道法蘭的連接
2. Connection of pipe flange
對于襯墊材料,不得使用厚紙、紙板、石棉繩、鉛麻和油氈紙。墊圈材料應(yīng)盡量減少接頭。墊片材料的接頭應(yīng)采用梯形或榫頭連接,并應(yīng)粘接牢固。法蘭被均勻壓縮后,墊片材料的寬度應(yīng)與風(fēng)道內(nèi)壁齊平。風(fēng)管與潔凈室天花板、隔墻和其他圍護(hù)結(jié)構(gòu)之間的接縫應(yīng)緊密。
For gasket materials, thick paper, cardboard, asbestos rope, lead hemp and linoleum paper shall not be used. Gasket material shall minimize joints. The joints of gasket materials shall be connected by trapezoid or tenon, and shall be firmly bonded. After the flange is uniformly compressed, the width of the gasket material shall be flush with the inner wall of the air duct. Joints between air ducts and clean room ceilings, partitions and other enclosures should be tight.
3、風(fēng)管系統(tǒng)應(yīng)有良好的接地措施
3. The air duct system shall have good grounding measures
穿過輔助生產(chǎn)室要嚴(yán)密,不得設(shè)置接口。輸送空氣溫度高于80℃時(shí),風(fēng)管應(yīng)按設(shè)計(jì)規(guī)定采取保護(hù)措施。風(fēng)管測量孔應(yīng)設(shè)置在便于測量和觀察的位置;天花板風(fēng)管上的測量孔應(yīng)留出相應(yīng)位置的活動(dòng)天花板或檢查門。當(dāng)隔熱風(fēng)管采用金屬法蘭和金屬加強(qiáng)件時(shí),外露部分應(yīng)采取措施防止冷橋冷凝。
濟(jì)南通風(fēng)管道加工
Passing through the auxiliary production room shall be tight and no interface shall be set. When the conveying air temperature is higher than 80 ℃, protective measures shall be taken for the air duct according to the design provisions. The air duct measuring hole shall be set at the position convenient for measurement and observation; The measuring hole on the ceiling duct shall be reserved with a movable ceiling or inspection door at the corresponding position. When metal flanges and metal reinforcements are used for heat insulation air duct, measures shall be taken for exposed parts to prevent cold bridge condensation.
4、風(fēng)管系統(tǒng)應(yīng)檢查是否漏氣
4. The air duct system shall be checked for air leakage
這是安裝空調(diào)的環(huán)節(jié),但也是一個(gè)重要的環(huán)節(jié),所以業(yè)主在接受空調(diào)時(shí)一定不能忽視這一環(huán)節(jié),在風(fēng)管安裝完成后,應(yīng)仔細(xì)檢查,防止漏風(fēng)。
This is the link of installing the air conditioner, but it is also an important link, so the owner must not ignore this link when accepting the air conditioner. After the installation of the air duct, it should be carefully checked to prevent air leakage.
5、風(fēng)管維護(hù)常識(shí)
5. Common sense of air duct maintenance
風(fēng)管安裝后,暫時(shí)未安裝的風(fēng)管開口、過濾器開口等開口部位應(yīng)及時(shí)用塑料布妥善包裹,防止現(xiàn)場灰塵進(jìn)入清潔后的風(fēng)管,造成風(fēng)管二次污染。
After the installation of air duct, the openings of air duct and filter that are not installed temporarily shall be properly wrapped with plastic cloth in time to prevent dust from entering the cleaned air duct and causing secondary pollution of the air duct.

上一篇:濟(jì)南通風(fēng)管道加工玻璃纖維復(fù)合材料風(fēng)管型號(hào)制作
下一篇:油煙凈化器配套風(fēng)機(jī)怎么選擇合適的?