通風管道的安裝怎么把位置定好?

來源:http://www.adr7.cn/     發(fā)布時間:2023-03-27  

在許多飯店的外邊我們會看到有一個很大的排煙管來排除無用的廢氣,但是大家知道嗎
"Outside many hotels, we can see a large smoke exhaust pipe to remove useless exhaust gas, but did you know?"
高層建筑的通風排煙管道設(shè)施應分為機械排煙設(shè)施和可開啟外窗的自然排煙設(shè)施。
Ventilation and smoke exhaust pipe facilities in high-rise buildings should be divided into mechanical smoke exhaust facilities and natural smoke exhaust facilities that can open external windows.
房間的機械排煙系統(tǒng)是按防煙分區(qū)設(shè)置的。
The mechanical smoke exhaust system of the room is arranged according to the smoke prevention zones.
(1)一類高層建筑和建筑高度超過32m 的二類高層建筑的下列部位應設(shè)排煙設(shè)施:
(1) Smoke exhaust facilities shall be provided in the following parts of Class I high-rise buildings and Class II high-rise buildings with a building height exceeding 32m:
濟南通風管道加工
1)長度超過20m 的內(nèi)走道;
1) Internal walkways exceeding 20m in length;
2)面積超過100m2,且經(jīng)常有人停留或可燃物較多的房間;
2) Rooms with an area of more than 100m2 and frequently occupied or with a large amount of combustibles;
3)高層建筑的中庭和經(jīng)常有人停留或可燃物較多的地下室。
3) The atrium of high-rise buildings and the basement where there are often people staying or there are many combustibles.
(2)通風、空氣調(diào)節(jié)系統(tǒng)應采取防火、防煙措施。
(2) Fire and smoke prevention measures shall be taken for ventilation and air conditioning systems.
(3)一類高層建筑和建筑高度超過32m 的二類高層建筑的下列部位,應設(shè)置機械排煙設(shè)施:
(3) Mechanical smoke exhaust facilities shall be provided in the following parts of Class I high-rise buildings and Class II high-rise buildings with a building height exceeding 32m:
無直接自然通風,且長度超過20m 的內(nèi)走道或雖有直接自然通風,但長度超過60m 的內(nèi)走道;
Internal walkways with no direct natural ventilation and a length of more than 20m or internal walkways with direct natural ventilation but a length of more than 60m;
面積超過100m2,且經(jīng)常有人停留或可燃物較多的地上無窗房間或設(shè)固定窗的房間;
Rooms without windows or with fixed windows on the ground that have an area of more than 100m2 and often have people staying or there are many combustibles;
不具備自然排煙條件或凈空高度超過12m 的中庭;
Atrium without natural smoke exhaust conditions or with a headroom exceeding 12m;
除利用窗井等開窗進行自然排煙的房間外,各房間總面積超過200m2 或一個房間面積超過50m2,且經(jīng)常有人停留或可燃物較多的地下室。
Except for rooms with windows such as window wells for natural smoke exhaust, the total area of each room exceeds 200m2 or the area of a room exceeds 50m2, and there are often people staying or there are many combustibles in the basement.
設(shè)置在高層建筑內(nèi)的通風排煙管道設(shè)施,應具備以下要求:
Ventilation and smoke exhaust pipe facilities installed in high-rise buildings should meet the following requirements:
(1)排煙口應設(shè)在頂棚上或靠近頂棚的墻面上,且與附近出口沿走道方向相鄰邊緣之間的水平距離不應小于1.50m。設(shè)在頂棚上的排煙口,距可燃構(gòu)件或可燃物的距離不應小于1.00m。
(1) The smoke exhaust outlet shall be located on the ceiling or on the wall adjacent to the ceiling, and the horizontal distance from the adjacent edge of the nearby emergency exit along the walkway direction shall not be less than 1.50m. The distance from the smoke outlet on the ceiling to combustible components or combustible materials should not be less than 1.00m.
排煙口平時關(guān)閉,并應設(shè)置有手動和自動開啟裝置。
The smoke outlet shall be normally closed and equipped with manual and automatic opening devices.
(2)防煙分區(qū)內(nèi)的排煙口距遠點的水平距離不應超過30m。
(2) The horizontal distance from the smoke outlet in the smoke control zone to the remote point should not exceed 30m.
在排煙支管上應設(shè)有當煙氣溫度超過280℃時能自行關(guān)閉的排煙防火閥。
The smoke exhaust branch pipe shall be equipped with a smoke exhaust fire damper that can be automatically closed when the smoke temperature exceeds 280 ℃.
(3)排煙風機可采用離心風機或采用排煙軸流風機,并應在其機房入口處設(shè)有當煙氣溫度超過280℃時能自動關(guān)閉的排煙防火閥。排煙風機應保證在280℃時能連續(xù)工作30min。
(3) The smoke exhaust fan can be a centrifugal fan or an axial flow smoke exhaust fan, and a smoke exhaust fire damper that can automatically close when the smoke temperature exceeds 280 ℃ should be installed at the entrance of the machine room. The smoke exhaust fan shall be able to operate continuously for 30 minutes at 280 ℃.
(4)機械排煙系統(tǒng)中,當任一排煙口或排煙閥開啟時,排煙風機應能自行啟動。
(4) In a mechanical smoke exhaust system, when any smoke outlet or smoke exhaust valve is opened, the smoke exhaust fan should be able to start automatically.